13. INPUT/OUTPUT OF DATA
B–64113EN–1/01
934
[Classification] Output signal
[Function] This signal indicates that the Series 0i/0i Mate has started data input.
[Output condition] This signal is set to 1 in the following case:
– When data input is started
This signal is set to 0 in the following case:
– When data input is terminated
This signal is a Power Mate control signal. The corresponding power
mate CNC side signal is EXWT <G098#3/G058#3> (the second address
being for Power Mate–MODEL D, and the first address for all other
models).
[Classification] Output signal
[Function] This signal notifies the power mate CNC that the input/output data
consists of programs.
[Output condition] This signal is set to 1 in the following case:
– When the input/output data consists of programs, and data input/output
has been started
This signal is set to 0 in the following case:
– When data input/output is terminated
This signal is a Power Mate control signal. The corresponding power
mate CNC side signal is EPRG <G098#4/G251#4> (the second address
being for Power Mate–MODEL D, and the first address for all other
models).
[Classification] Output signal
[Function] This signal notifies the power mate CNC that the input/output data
consists of macro variables.
[Output condition] This signal is set to 1 in the following case:
– When the input/output data consists of macro variables, and data
input/output has been started
Slave external write start
signal
EWTIO <F177#3>
Slave program selection
signal
EPRG <F177#4>
Slave macro variable
selection signal
EVAR <F177#5>