B–64113EN–1/01
4. REFERENCE POSITION ESTABLISHMENT
255
(d)During the reference point establishment operation of the angular
axis, the command in the perpendicular axis is invalid in the
manual reference point return.
(e) On angular axis control, if you use automatic setting of parameter
No.1883,1884 on reference point establishment (Prm. No.1819#2
(DATx)=1), please establish reference point of perpendicular axis
after reference point establishment and return of angular axis.
#7
1815
#6 #5 #4 #3
DCRx
#2
DCLx
#1
OPTx
#0
[Data type] Bit axis
OPTx Position detector
0 : A separate pulse coder is not used.
1 : A separate pulse coder is used.
DCLx As a separate position detector, the linear scale with reference absolute
addressing mark (A/B phase)/the Linear scale with distance–coded
reference marks (serial) is:
0 : Not used.
1 : Used
CAUTION
When using the linear scale with reference absolute
addressing marks (A/B phase) or the linear scale with
distance–coded reference marks (serial, full closed
system), also set the OPTx parameter (bit 1 of parameters
No.1815) to ’1’. But when using the linear scale with
distance–coded reference marks (serial, linear motor
system), please set the OPTx parameter (bit 1 of
parameters No.1815) to ’0’.
DCRx As a scale with absolute addressing referenced marks:
0 : The linear scale is used.
1 : The rotary encoder is used.
CAUTION
1 Please set parameter DCLx to ’1’, too.
2 The rotary encoder with distance–coded reference marks
(serial) is unavailable.
Parameter