B–64113EN–1/01
12. DISPLAY/SET/EDIT
855
(3)Count type
Pressing the [TYPE] causes the following count types to be displayed
as soft keys. Select the desired one and press the [EXEC] soft key to
set it up.
Software Meaning Display
[EFFECT] No counting takes place (the counter is halted). – – –
[ALL–AX] Counting continues unconditionally
(nonstop counting).
ALL
[LIV] Counting continues as long as the power is on. LIV
[RUN] Counting continues during run time. RUN
[CUT] Counting continues during cutting time. CUT
NOTE
1 If an attempt is made to enter data for a null item, the
warning message “EDIT REJECTED” appears.
2 The [INPUT] and [+INPUT] soft keys do not function for
count type.
3 Leap year is not a ccounted for in the counting, and can
cause a 24–hour error in the counting.
The registered data related to the maintenance service life can be output
to an external unit, using the [PUNCH] soft key. Similarly, data can be
input from an external unit, using the [READ] soft key. These
input/output operations can be performed on the status, setting, and menu
(machine maintenance only) screens.
EDIT *** ***** *** **** 19:27:05
[ ][ READ ][ PUNCH ][ ][ ]
[ ][ ][ ][ CAN ][ EXEC ]
In EDIT mode, pressing the [PUNCH] soft key causes registered data to
be output in the following formats.
f Status and setting screens
G10 L60 P01 Aa Rr [n] Qq ;
G10 L60 P02 Aa Rr [n] Qq ;
G10 L60 P03 Aa Rr [n] Qq ;
:
Inputting and outputting
the registered data
D Data output
Format