8. AUXILIARY FUNCTION
B–64113EN–1/01
484
[Classification] Output signal
[Function] These signals report that second auxiliary functions have been specified.
[Output condition] For the output conditions and procedure, see the description of “Basic
procedure” above.
[Classification] Input signal
[Function] This signal reports the completion of a miscellaneous function,
spindle–speed function, tool function, second auxiliary function, or
external operation function.
[Operation] For the control unit operation and procedure when this signal goes “1”,
see the description of “Basic procedure” above.
The FIN signal must remain “1” for a certain time (TFIN, which is set by
a parameter No. 3011) or longer. The FIN signal driven “1” is ignored if
the FIN signal goes “0” before TFIN elapses.
WARNING
Only one end signal is used for all functions above. The end
signal must go “1” after all functions are completed.
[Classification] Output signal
[Function] These signals report that all commands (such as move commands and
dwell) are completed except those miscellaneous functions,
spindle–speed functions, 2nd auxilialy functions tool functions, and so
forth that are contained in the same block and have been sent to the PMC.
They also report that the end signal from the PMC is being awaited.
[Output condition] The DEN signal turns to “1” when:
· Waiting for the completion of miscellaneous functions, spindle–speed
functions, tool functions, 2nd auxilialy functions and all other
commands in the same block are completed, and the current position is
in the in–position.
Second auxiliary
function code signals
B00 to B31
<F030–F033>
Second auxiliary
function strobe signal
BF <F007#4> (T series)
<F007#7> (M series)
End signal FIN <G004#3>
Distribution end signal
DEN <F001#3>