15. PMC CONTROL FUNCTION
B–64113EN–1/01
1030
NOTE
The above setting is effective only when the NAHx bit (bit 7
of parameter No. 1819) is set to 0.
G8R If a rapid traverse command is specified for a PMC–controlled axis,
look–ahead control is:
0 : Disabled.
1 : Enabled.
NOTE
The above setting is effective only when the NAHx bit (bit 7
of parameter No. 1819) is set to 0.
DSL If an axis exchange is attempted while the selection of a PMC–controlled
axis is inhibited,
0 : The attempt fails and a P/S alarm No. 139 occurs.
1 : The axis exchange is executed for the axes that belong to an
unspecified path.
NCI During deceleration along an axis controlled by the PMC, the in–position
check is:
0 : Performed.
1 : Not performed.
NDI When diameter programming is selected for a PMC controlled axis, under
PMC axis control:
0 : Radius programming is used to specify the travel distance and
feedrate.
1 : Diameter programming is used to specify the travel distance and
feedrate.
NOTE
While the CDI bit (bit 1 of parameter No. 8005) is held to 0,
the NDI bit is valid for an axis of diameter programming (the
DIAx bit (bit 3 of parameter No. 1006) is set to 1).
#7
MFD8005
#6 #5 #4 #3 #2 #1
CDI
#0
EDC
[Data type] Bit
EDC Under PMC axis control, the external deceleration signal is:
0 : Ineffective.
1 : Effective.
CDI When diameter programming is selected for a PMC controlled axis, under
PMC axis control:
0 : Radius programming is used to specify the travel distance and
feedrate.
1 : Diameter programming is used to specify the travel distance, and
radius programming is used to specify the feedrate.