B–64113EN–1/01
12. DISPLAY/SET/EDIT
863
(1)The parameter set supporting screen cannot be used to read or punch
parameters.
(2)Standard value setting can be done only for AXIS SETTING on the
parameter set supporting screen and items on other screens. The
conventional parameter screen cannot be used to specify standard
values.
(3)If no standard value is available for the parameter you select with the
cursor, pressing the [INIT] soft key results in the following warning
message being displayed: ”There is no standard value.”
(4)If no standard value is available for the group you select, pressing the
[G_INIT] soft key results in the following warning message being
displayed: ”There is no standard value.”
(5)The machining parameter tuning screen does not appear unless the a
machining condition select option is available.
Parameters required for machine launching
Menu
item
Group
Parameter
No.
Brief description
SETTING
1001#0 Linear–axis least command increment
0: Millimeter machines
1: Inch machines
1002#1 Reference position return without
dogs
0: Disable
1: Enable (all axes)
1004#1 Least input increment and least com-
mand increment settings
0: IS–B
1: IS–C
1005#0 Automatic operation (other than G28)
with no origin established is re-
sponded with:
0: An alarm (No. 224)
1: No alarm
1005#1 Reference position return without
dogs
0: Disable (individual axes)
1: Enable (individual axes)
1006#0 Selecting linear or rotation axis
0: Linear axis
1: Rotation axis
1006#3 Specifying a move amount type for in-
dividual axes
0: Radius type
1: Diameter type
1006#5 Direction of a reference position return
for individual axes
0: Positive direction
1: Negative direction
Notes