13. INPUT/OUTPUT OF DATA
B–64113EN–1/01
924
(2) When an alarm is issued by the Series 0i/0i Mate (including the case
where processing is stopped by external read/punch signal EXSTP)
Steps 1) to 10) are the same as those for ordinary input/output.
11) When the Series 0i/0i Mate issues an alarm, or when
external read/punch stop signal EXSTP is set to 1, slave
read/write stop signal ESTPIO is set to 1.
12) The Series 0i/0i Mate waits for the external I/O device
control function of the power mate CNC to terminate. The
Series 0i/0i Mate merely waits until the external I/O device
control function of the power mate CNC terminates.
13) When the external I/O device control function of the power
mate CNC terminates, Power Mate read/write in–progress
signal BGION is set to 0.
14) The Series 0i/0i Mate sets slave I/O Link selection signal
IOLNK and slave read/write stop signal ESTPIO to 0.
15) I/O Link specification signal IOLS and I/O Link
confirmation signal IOLACK are set to 0.