B–64113EN–1/01
1. AXIS CONTROL
79
[Valid data range] –99999999 to 99999999
Set the coordinate values of the reference positions in the machine
coordinate system.
1722 Rapid traverse deceleration rate at inter–rapid traverse block overlap
[Data type] Byte axis
[Unit of data] %
[Valid data range] 0 to 100
If a high–speed G53 command (G53 P1) block is followed by a rapid
traverse block, the latter block (rapid traverse) is executed after the
feedrate specified for each axis in the G53 P1 block has decreased to the
deceleration rate specified in this parameter.
NOTE
1 Enabling the high–speed G53 function does not require
setting the RTO parameter (bit 4 of parameter No. 1601) for
enabling inter–rapid traverse block overlap to 1.
2 If the RTO parameter (bit 4 of parameter No. 1601) is set to
1, a value specified in parameter No. 1722 is used also for
ordinary inter–rapid traverse block overlap.
WARNING
Since the machine coordinate system must be set before
the G53 command is specified, at least one manual
reference position return or automatic reference position
return by the G28 command must be performed after the
power is turned on. This is not necessary when an
absolute–position detector is attached.
OPERATOR’S MANUAL
(M series) (B–64124EN)
II.7.1
MACHINE COORDINATE
SYSTEM
OPERATOR’S MANUAL
(T series) (B–64114EN)
II.7.1
MACHINE COORDINATE
SYSTEM
OPERATOR’S MANUAL
(M series) (B–64144EN)
II.7.1
MACHINE COORDINATE
SYSTEM
OPERATOR’S MANUAL
(T series) (B–64134EN)
II.7.1
MACHINE COORDINATE
SYSTEM
Warning
Reference item