B–64113EN–1/01
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
393
#7
G023
#6 #5 #4 #3
HNDLF
#2 #1 #0
G118 *+ED4 *+ED3 *+ED2 *+ED1
G120 *–ED4 *–ED3 *–ED2 *–ED1
G101 *+ED24 *+ED23 *+ED22 *+ED21
G103 *–ED24 *–ED23 *–ED22 *–ED21
G107 *+ED34 *+ED33 *+ED32 *+ED31
G109 *–ED34 *–ED33 *–ED32 *–ED31
#7
1005
#6 #5
EDMx
#4
EDPx
#3 #2 #1 #0
[Data type] Bit axis
EDPx External deceleration signal in the positive direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
EDMx External deceleration signal in the negative direction for each axis
0 : Valid only for rapid traverse
1 : Valid for rapid traverse and cutting feed
#7
1405
#6 #5
EDR
#4 #3 #2 #1 #0
[Data type] Bit
EDR Selects a parameter for setting the external deceleration applied during
interpolation type rapid traverse.
0 : Parameter No. 1426 is used for setting the external deceleration rate
applied during interpolation type rapid traverse.
1 : The first axis of parameter No. 1427 is used for setting the external
deceleration rate applied during interpolation type rapid traverse.
(Similarly, for external deceleration 2 and 3, the first axis of the external
deceleration rate parameter for rapid traverse is used if EDR is set to 1.)
#7
1406
#6 #5 #4 #3 #2 #1
ED3
#0
ED2
[Data type] Bit
ED2 External deceleration 2 is:
0 : Disabled.
1 : Enabled.
Signal address
Parameter