B–64113EN–1/01
15. PMC CONTROL FUNCTION
1019
[Classification] Output signal
[Function] This signal is set to “1” when the feedrate override is 0%.
[Classification] Input signal
[Function] When this signal is set to “1” during execution of the skip cutting
command, the block being executed is immediately stopped and the next
block is executed. Bit 7 (SKE) of parameter No. 8001 can be used to select
whether to use signal SKIP, which is the common skip signal for the PMC
and CNC, or PMC–specific skip signal ESKIP.
[Classification] Output signal
[Function] These signals are set to “0” when the tool is moving with a command from
the PMC. The signals are set to “1” when the tool is not moving, except
when it is stopped by an axis control temporary stop signal ESTPg during
the execution of a move command.
[Classification] Output signal
[Function] This signal is set to “1” when the input buffer contains a command block.
[Classification] Output signal
[Function] When the control axis selection status signal *EAXSL is set to “1”, signal
EACNTn corresponding to the axis being controlled is set to “1”.
31 Override 0% signal
EOV0
32 Skip signal ESKIP
33 Distribution
completion signals
EADEN1 to EADEN4
34 Buffer full signal
EABUFg
35 Controlling signals
EACNT1 to EACNT4