B–64113EN–1/01
12. DISPLAY/SET/EDIT
861
Make sure that the setting screen is ”parameter write enabled.”
Select the MDI mode, and place the cursor on the parameter you want to
specify.
Enter data, using numeric keys, and press the [INPUT] soft key or the
[INPUT] key on the MDI.
[<][][][][] [] [>]
NO. SRH INIT G_INIT INPUT
Press the [–] soft key several times until the following soft keys appear.
[<][][][][] [] [>]
PARAM DGNOS PMC SYSTEM (OPRT)
Press the [PARAM] soft key to display the conventional parameter
screen.
To return to the parameter tuning menu screen after an item is selected,
operate as follows:
[<][][][][] [] [>]
NO. SRH INIT G_INIT INPUT
Press the [+] soft key to display the [MENU] soft key.
[<][][][][] [] [>]
MENU
Pressing the [MENU] soft key displays the parameter set supporting
menu screen.
This operation can let you return to the parameter set supporting menu
screen also from the FSSB (AMP), FSSB (AXIS), SERVO SETTING,
SERVO TUNING, and SPINDLE TUNING screens.
Standard values can be specified for parameters, using soft keys.
There are two methods. The first method is to specify a standard value
only for the parameter selected with the cursor. The second method is to
specify standard values for all parameters in a group.
The standard values are those recommend by FANUC. It is impossible
to specify standard values specific to an individual user.
The conventional parameter screen allows no standard value to be set up.
Select the MDI mode.
Place the cursor on the parameter for which you want to specify a standard
value.
Make sure that the following soft keys are displayed, and press the [INIT]
soft key.
[<][][][][] [] [>]
NO. SRH INIT G_INIT INPUT
The standard value you entered is displayed on the key input line, and the
following warning message appears: ”Do you really want to perform
initialization?”
Press the [EXEC] soft key to set up the standard value.
[<][][][][] [] [>]
CAN EXEC
If you want to quit setting the standard value, press the [CAN] soft key.
If no standard value is available for the parameter selected with the cursor,
pressing the [INIT] soft key results in the following warning message
being displayed: ”No standard value is available.”
Entering parameters
Displaying the
conventional parameter
screen
Displaying the menu
screen
Setting initial values
D Setting initial values for
individual parameters