B–64113EN–1/01
12. DISPLAY/SET/EDIT
805
3122 Time interval used to record data in the operation history
[Data type] Word
[Unit of data] Minutes
[Valid data range] 0 to 1439
Time data is recorded in the operation history at set intervals. When 0 is
specified in this parameter, 10 minutes is assumed as the default.
#7
3206
#6 #5 #4
OHS
#3 #2 #1 #0
[Data type] Bit
OHS 0 : Operation history signal selection is not linked to parameters.
Signals are selected as or deselected from operation history targets on
the operation history signal selection screen. Changing any
parameter does not affect operation history signal selection.
1 : Operation history signal selection is linked to parameters.
Operation history signal selection can be made both on the operation
history signal selection screen and through parameters.
NOTE
Setting this parameter to 1 causes the current operation
history signal selection data to be reflected to parameter
Nos. 12801 to 12900.
12801 Operation history signal selection signal type (No. 01)
12802 Operation history signal selection signal type (No. 02)
12803 Operation history signal selection signal type (No. 03)
::
12820 Operation history signal selection signal type (No. 20)
[Data type] Byte
[Valid data range] 0 to 10
Specify signal types for operation history signal selection. The following
table lists the signal types and corresponding parameter values.
Signal type Parameter value
Not selected 0
G0000 to G0255 1
F0000 to F0255 3
Y0000 to Y0127 5
X0000 to X0127 6