B–64113EN–1/01
1. AXIS CONTROL
74
Number DescriptionMessage
466 n AXIS : MOTOR/AMP
COMBINATION
The maximum current rating for the am-
plifier does not match that for the motor.
467 n AXIS : ILLEGAL SET-
TING OF AXIS
The servo function for the following has
not been enabled when an axis occu-
pying a single DSP is specified on the
axis setting screen.
1. High–speed current loop
(bit 0 of parameter No. 2004 = 1)
2. High–speed interface axis
(bit 4 of parameter No. 2005 = 1)
468 HI HRV SETTING
ERROR(AMP)
Use of high–speed HRV is specified for
a controlled axis of an amplifier which
does not support high–speed HRV.
Number Message Description
5134 FSSB : OPEN READY
TIME OUT
The FSSB did not become ready to
open during initialization.
5135 FSSB : ERROR MODE The FSSB entered an error mode.
5136 FSSB : NUMBER OF
AMPS IS SMALL
The number of amplifiers recognized
by the FSSB is insufficient, compared
with the number of controlled axes.
5137 FSSB : CONFIGURATION
ERROR
The FSSB detected a configuration er-
ror. The address conversion table val-
ue (ATR) setting (parameter Nos. 1910
to 1919 and 1970 to 1979) for a slave
axis does not match the type of a slave
axis actually connected to the FSSB.
5138 FSSB : AXIS SETTING
NOT COMPLETE
Axis setting has not been performed in
automatic setting mode. Perform axis
setting using the FSSB setting screen.
5139 FSSB : ERROR The initialization of the servo was not
completed normally. Probable cases
are a defect of optical cable or a mis-
take of the connection between the am-
plifier and other modules.
5197 FSSB : OPEN TIME OUT The FSSB did not open when the CNC
had allowed the FSSB to open.
D P/S alarms