B–64113EN–1/01
13. INPUT/OUTPUT OF DATA
895
Note) The EOB output patterns are as shown below:
NCR CRF EOB output format
0 0 “LF” “CR” “CR”
0 1 “CR” “LF”
1 0 “LF”
1 1 “CR” “LF”
NCR Output of the end of block (EOB) in ISO code
0 : LF, CR, CR are output.
1 : Only LF is output.
ND3 In DNC operation, a program is:
0 : Read block by block. (A DC3 code is output for each block.)
1 : Read continuously until the buffer becomes full. (A DC3 code is
output when the buffer becomes full.)
NOTE
In general, reading is performed more efficiently when ND3
set to 1. This specification reduces the number of buffering
interruptions caused by reading of a series of blocks
specifying short movements. This in turn reduces the
effective cycle time.
IOP Specifies how to stop program input/output operations.
0 : An NC reset can stop program input/output operations.
1 : Only the [STOP] soft key can stop program input/output operations.
(An reset cannot stop program input/output operations.)
ENS Action taken when a NULL code is found during read of EIA code
0 : An alarm is generated.
1 : The NULL code is ignored.
#7
0110
#6 #5 #4 #3 #2 #1 #0
IO4
[Data type] Bit
IO4 Separate control of I/O channel numbers is:
0: Not performed.
1: Performed.
If the I/O channels are not separately controlled, set the input/output
device in parameter No. 20.
If the I/O channels are separately controlled, set the input device and
output device in the foreground and the input device and output device in
the background in parameters No. 20 to No. 23 respectively.
Separate control of I/O channels makes it possible to perform background
editing, program input/output, and the like during the DNC operation.