12. DISPLAY/SET/EDIT
B–64113EN–1/01
862
Select the MDI mode.
Make sure that the following soft keys are displayed, and press the
[G_INIT] soft key.
[<][][][][] [] [>]
NO. SRH INIT G_INIT INPUT
Instead of a help message, the following message appears:
The following soft key group appears, and the following warning
message appears: ”Do you really want to perform initialization?”
[<][][][][] [] [>]
CAN EXEC
Pressing the [EXEC] soft key causes standard values to be set up for the
selected group.
In this case, no standard value is displayed on the key input line. Instead,
the setting is automatic. Be extremely careful when using this method.
If you want to quit setting the standard values, press the [CAN] soft key.
Before starting to set up standard values for an entire group, put the
machine at an emergency stop for safety purposes.
TUNING lets you display the servo, spindle, and machining parameter
tuning screens readily, so you can make adjustments easily.
On the parameter tuning screen menu, place the cursor on the desired
tuning screen item and press the [SELECT] soft key to display the
corresponding screen.
SERVO TUNING: The servo tuning screen is displayed.
SPINDLE TUNING: The spindle tuning screen is displayed.
APC/AI TUNING: The machining parameter tuning screen (for APC,
AI–APC, and AI contour control) is displayed.
NOTE
The machining parameter tuning screen (for APC, AI–APC,
and AI contour control) will not be displayed unless the
machining condition select option is available.
#7
3195
#6 #5 #4 #3 #2
CPR
#1 #0
[Data type] Bit
CPR Pressing the [SYSTEM] function key:
0 : Displays the parameter setting assistance screen.
1 : Does not display the parameter setting assistance screen.
D Specifying standard
values for an entire
group
TUNING
Parameter