B–64113EN–1/01
1. AXIS CONTROL
49
(1)This function is enabled after a manual reference position return or an
automatic reference position return with the same sequence as that of
a manual reference position return is performed. When an absolute
position detector is used, however, the function is enabled after the
power is turned on.
(2)When the machine moves to the reference position in the reference
position return direction, set the absolute value of the pitch error
compensation pulse to 0.
(3)When this function and backlash compensation are used at the same
time, the pulse resulting from backlash compensation is superimposed
on the compensation pulse when the travel direction is reversed.
(4)When this function is used for a rotation axis, the sum of the pitch error
compensation amounts per rotation about the rotation axis must be 0
for both the positive and negative directions.
(5)The function cannot be used with the distance coded linear scale
function.
Note