B-75074EN/04 OPERATION 2.SCREEN OPERATION
- 243 -
<3> Warning and alarm lamps
(1) Warning lamp:
If an error occurs in i CELL background processing such as
machining result collection, the lamp blinks in yellow.
Clicking the warning lamp activates the warning log display
screen, and displays an error log.
(2) Alarm lamp:
If an alarm is raised in any NC connected, the alarm lamp
blinks in red. If an operator message is issued, the lamp
blinks in magenta. If there are both an alarm state and an
operator message, the lamp blinks in the color of alarm, that
is, in red. Clicking the blinking alarm lamp causes the alarm
message screen to appear. The screen first shows the
information of an NC with the smallest machine number of
the NCs having an alarm state or operator message. If there
are both an alarm state and an operator message, the
information of an NC in an alarm state takes precedence.
<4> Message indication line
The message indication line displays an operation method or error
message. If a message is displayed in this line, operation is
disabled until you click the message confirmation button
described in <5> below.
<5> Message confirmation button
The message confirmation button appears only when a message is
displayed. (The figure displays the button for explanation.) Upon
confirmation of a message displayed in the message indication line,
click this button.
<6> Machine number selection
Select a machine number or machine name in the combo box.
Depending on the screen, a combo box for path number selection
is also displayed.