62/98
SHEET
DESCRIPTION
DESIGN
DATE
EDIT
01
FANUC LTD.
DRAW.NO.
Matsukura
Newl
re
istered
TITLE:
FANUC CIMPLICITY i CELL
OPERATOR’S MANUAL
05.05.19
B-75074EN/04-2
Examples)
Machine information in the
Configuration dialog box
Machine number output to a log
Machine
number
Path number Path-specific serial
number
IP address-specific
number
1 1 1 1
1 2 2
2
2 3 2
3 1 4 3
5 1 5 4
The machine number to be output to a log can be set with the appropriate
project property.
Refer to Section 2.4, "PROJECT PROPERTY", in Part III, "SETTING", in
the i
CELL Operator's Manual.
The following explains logs in detail.
5.5.7.1 PWRLOG – CNC power status
Changes in the power ON/OFF state of each CNC are output to CimVrtlCnc
Detail Log.
The log is output only when a power status change occurs.
It is used to survey the power status acquisition process.
Log format
Power Log: Old=previous New=present Reboot=restart Msg=message
Old
Previous power status.
0 = OFF, 1 = ON
New
Present power status.
0 = OFF, 1 = ON
ReBoot
Whether a restart has been done.
0 = No restart done, 1 = Restart done
Msg
Whether a power message has been sent.
0 = Not sent, 1 = Sent
NOTE
Creating a log causes communication processing speed to
decrease. Set the log creation options only if required; usually,
refrain from creating logs other than those created by default.