B-75074EN/04 USER CUSTOMIZE 2.ADDING SCREENS
- 405 -
- Explanation
When this method has been executed successfully, i CELL settings are
written into Value(). The first dimension of a two-dimensional array
represents machines and the other dimension represents the settings of
each machine.
i CELL settings for the number of machines set in the
public variable mDispMachine are set in the array. See the properties
starting with piCELL… for the meaning of each array element.
- Return value
A Boolean value is returned. When the processing is successful, True is
returned. When the processing fails, False is returned. When the
processing fails, the cause is set in the public variable mErrorMessage.
Initialize
Performs initialization processing.
- Syntax
object.Initialize Path
- Setting
Path
Set the %iCELL%\CimProject\ directory by using a character string
expression. It is assumed that under this directory, a directory
storing the ini file under the fanuc directory is configured.
When the CIMPLICITY execution project environment
variable ”SITE_ROOT” is specified, this argument is omissible.
- Explanation
When this method has been executed successfully, the values of the
public variables indicated below become valid. For details of each
public variable, see Subsection 2.6.1.2, "Public variables".
mLanguage
Display language
mDispMachine
Maximum number of machines
mMachineItemCount
Number of machine setting items
mScrIdCount
Number of screens within the screen master
mScrOverViewId
Screen ID specified for overview with a selected
machine
mDirectory
Directory of a setting file
- Return value
A Boolean value is returned. When the processing is successful, True is
returned. When the processing fails, False is returned. When the
processing fails, the cause is set in the public variable mErrorMessage.
MachineRead
Reads machine settings.
- Syntax
object.MachineRead Value()